Facility Coding for Modifiers 52, 73, and 74
- By Emily Montemayor
- In Coding
- April 1, 2024
- Comments Off on Facility Coding for Modifiers 52, 73, and 74
Professional fee-for-service guidelines for modifiers do not apply in the outpatient setting.
Reduced, unsuccessful, aborted, cancelled … which is it? What are the criteria for using modifiers 52, 73, and 74?
These questions are common within the facility coding world, and it seems the answers are never clear. Mix in confusion with coding guidance pertaining to pro fee coding and you are falling down a rabbit hole. Let’s dive into the coding criteria for the applicable scenarios and answer once and for all when to use each of these modifiers for facility claims.
Modifier Definitions
Let’s begin with the basic modifier definitions pertaining to facility criteria only. The following guidelines are only for ambulatory surgical centers (ASCs) and outpatient hospital use. Physician coding would be reported with the appropriate physician modifiers.
Modifier 52: This modifier indicates a partial reduction, cancellation, or discontinuation of services for which anesthesia was not planned, or discontinuation of radiology procedures and other services that do not require anesthesia.
- A requirement for use of this modifier is that anesthesia was neither planned nor used, even for reduced procedure components.
Modifier 73: This modifier indicates the procedure was discontinued or terminated before planned anesthesia had been provided.
- The medical record documentation should reflect the reason for the cancellation.
- The patient must have been prepared for the procedure and taken to the room where the procedure was to be performed to report modifier 73.
- Modifier 73 may not be used if anesthesia was not planned for the procedure.
Note: Procedures appended with modifier 73 will be reimbursed at 50 percent of the applicable fee schedule rate for the facility.
Modifier 74: This modifier indicates the procedure was discontinued or terminated after planned anesthesia had been provided.
- The patient must have been prepared for the procedure and taken to the room where the procedure was to be performed.
- Do not use modifier 74 if anesthesia was not planned for the procedure.
Note: Procedures appended with modifier 74 will be reimbursed at 100 percent of the applicable fee schedule rate for the facility.
These guidelines do not apply to elective cancellations, which are not reportable.
Coding and Billing for Facility Services
From Medicare’s perspective, anesthesia furnished in a hospital outpatient department includes:
- Local, regional block(s)
- Moderate sedation/analgesia (i.e., conscious sedation)
- Deep sedation/analgesia
- General anesthesia
Reduced Surgical Procedures
No modifier should be used when a surgical procedure that is performed with anesthesia is reduced but carried out as intended (i.e., without disturbing the identification of the basic service).
Note: Modifier 52 is used for these scenarios on the pro fee side, but not the facility side.
Guidance in AHA HCPCS Coding Clinic (2012, vol. 12, no. 1) tells us to use modifier 74 for these situations, not modifier 52. The American Hospital Association updated this guidance in a later AHA HCPCS Coding Clinic (2021, vol. 21, No. 4). Per the revised guidance: “… there are no appropriate modifiers for facility use when a reduced procedure is carried out as intended.”
In another example, AHA HCPCS Coding Clinic (2021, vol. 21, no. 3) reiterates: “… it is not appropriate for the facility to report reduced services with Modifier 52 when a procedure, performed under anesthesia, has been completed as intended.”
Reduced procedure examples:
- An inherently bilateral procedure which was only intended to be performed as unilateral and no other code is available, such as tonsillectomy.
- Hemorrhoidectomy with internal/external components, and only the internal procedure is performed.
- Removal and replacement of one component in a multi-component device.
Failed and Unsuccessful Procedures
The guidance regarding appropriate use of modifiers concerning attempted and failed/unsuccessful procedures differs from aborted/reduced procedures.
Per AHA HCPCS Coding Clinic (2016, vol. 16, no. 1), “When a procedure is considered to have ‘failed’ or stated as ‘unsuccessful’ this indicates that the expected result(s) of the procedure were not achieved. Although the procedure might be described as a failed or unsuccessful procedure, in all actuality the procedure was performed and therefore should be coded.”
The articles goes on to explain, “Sometimes several unsuccessful attempts are made during the same operative episode to perform a procedure and finally the last attempt is successful. In this instance, only one unit of a single code would be reported for the procedure successfully accomplished, regardless of the numerous attempts because the unsuccessful attempts would be considered a part of the successful procedure.”
Examples:
- A failed or unsuccessful attempt to reduce a fracture or dislocation.
- A failed or unsuccessful attempt to perform an external cephalic version.
Terminated, Discontinued, or Aborted Procedures
A discontinued (i.e., cancelled, terminated, or aborted) procedure is when the patient was taken to the treatment room for a planned procedure and the procedure was initiated, but for some specific reason the procedure was either canceled or not completed. There can be many causes for a discontinued procedure, from the patient changing their mind to undergo the procedure, to a negative reaction to anesthesia, to the patient experiencing a complication, such as excessive hemorrhaging, or the physician discovering a complication after surgery has begun.
Per AHA HCPCS Coding Clinic (2016, vol. 16, no. 1), “Similar to the failed/unsuccessful procedure, the specific discontinued procedure would be coded, but the difference is that a modifier (ie, 73, or 74) would be appended to the CPT code to report that the procedure or service was discontinued or cancelled at the physician’s discretion before or after the administration of anesthesia, as applicable.”
The same article states that the coder must review the documentation thoroughly to identify whether:
- “the procedure was planned and/or started
- the procedure was cancelled or discontinued
- the procedure was completed but desired results were not achieved
- the procedure was cancelled or discontinued before or after the administration of anesthesia”
Based on the definitions provided above, we would select modifier 73/74 for surgical procedures aborted before/after anesthesia is administered.
Modifier 73 example:
A 56-year-old patient with an inguinal hernia presents for open initial inguinal hernia repair. The patient is taken to the operative room, surgically prepped, and prior to general anesthesia, the patient is found to have high blood pressure. Due to this finding, the provider decides to cancel the procedure.
In this case, you would assign the appropriate CPT® code with modifier 73 appended.
Modifier 74 example:
A patient with right ureteral calculus presents for cystourethroscopy, lithotripsy, and stent placement. The patient is prepped and a general anesthetic is given. The scope is inserted; however, a stricture is encountered and, after multiple attempts, the provider withdraws the scope and cancels the procedure.
In this case, you would assign the appropriate CPT® code with modifier 74 appended.
Tip: Regarding aborted procedures when reviewing coding for colonoscopies, there is special guidance regarding the correct coding provided. When a colonoscopy is attempted and aborted, per CPT® coding guidance, the code selection will differ if the provider is able/unable to advance past the splenic flexure.
- If unable to be fully completed and ultimately aborted/discontinued prior to reaching the splenic flexure, then code the appropriate sigmoidoscopy code.
- If unable to be fully completed and ultimately aborted/discontinued beyond the splenic flexure, then apply modifier 74 to the appropriate colonoscopy code.
- If the scope reaches the cecum, a modifier is not necessary.
Multiple Procedures – Discontinued Procedure
Another area in which there is some confusion is when there are multiple procedures performed, and one is discontinued. There are a couple of scenarios to keep in mind to determine accurate coding:
- If multiple procedures are planned but none are performed, only the primary procedure is reported with the appropriate modifier (73 or 74).
- If one procedure is completed and a second is started but not completed, code the first procedure with no modifier and report the second procedure with modifier 74. Any additional planned procedures not started are not reported.
- Modifier 73 is considered valid on a maximum of one procedure code for the patient encounter.
- When a bilateral procedure is planned and is discontinued/terminated, only a unilateral procedure (the first side) may be reported with modifier 73. The second side is not reported. Do not report bilateral modifier 50 in combination with modifier 73 on the same procedure code.
Know the Rules for Modifiers
On the facility side, coding relates to the overhead costs and the coding will reflect the volume and intensity of resources used by the facility to provide the patient care. Just because a procedure is not fully performed or successful does not necessarily mean fewer resources were used. This is the reasoning behind the differences between the professional and facility coding criteria. Additionally, always check with the patient’s payer policy to confirm whether they follow the guidelines given in this article.
Resources:
Medicare Claims Processing Manual