ICD-10-PCS Code Range for Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device

ICD-10-PCS Code Range for Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device is medical classification list by Centers for Medicare and Medicaid Services (CMS).

ICD-10-PCS code range (0HW), contains ICD-10-PCS codes for Central Nervous System and Cranial Nerves, Medical and Surgical, Skin and Breast, Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.

PCS Tables

0HW

0 Medical and Surgical
H Skin and Breast
W Revision: Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Body Part Approach Device Qualifier
Character 4 Character 5 Character 6 Character 7
Body System (Character 4)
P Skin
Approach (Character 5)
X External
Substance (Character 6)
0 Drainage Device
7 Autologous Tissue Substitute
J Synthetic Substitute
K Nonautologous Tissue Substitute
Y Other Device
Qualifier (Character 7)
Z No Qualifier
Body System (Character 4)
Q Finger Nail
R Toe Nail
Approach (Character 5)
X External
Substance (Character 6)
0 Drainage Device
7 Autologous Tissue Substitute
J Synthetic Substitute
K Nonautologous Tissue Substitute
Qualifier (Character 7)
Z No Qualifier
Body System (Character 4)
S Hair
Approach (Character 5)
X External
Substance (Character 6)
7 Autologous Tissue Substitute
J Synthetic Substitute
K Nonautologous Tissue Substitute
Qualifier (Character 7)
Z No Qualifier
Body System (Character 4)
T Breast, Right
U Breast, Left
Approach (Character 5)
0 Open
3 Percutaneous
7 Via Natural or Artificial Opening
8 Via Natural or Artificial Opening Endoscopic
Substance (Character 6)
0 Drainage Device
7 Autologous Tissue Substitute
J Synthetic Substitute
K Nonautologous Tissue Substitute
N Tissue Expander
Y Other Device
Qualifier (Character 7)
Z No Qualifier

December 31, 1969
The Medicare Advantage organization says they are being held to unreasonable standards. Health Net of California Inc. was recently called out by the Office of Inspector General OIG for failing to subm... [ Read More ]
December 31, 1969
Reduce the clutter on your home page with one click. Codify offers a lot of tools on its home page but you dont always want all of them expanded at once. There is a simple way to maximize the tools yo... [ Read More ]
December 31, 1969
Strategies for unlocking a dialogue with physicians. As auditors we bridge the gap between medical coding accuracy and financial stability in healthcare organizations. Its our role to knock on the doo... [ Read More ]
December 31, 1969
Encourage patients to take stock of their relationship with alcohol. From Dry January and Dry July to Sober September and Sober October the monthlong abstinence trend of shunning alcohol has gained gr... [ Read More ]
December 31, 1969
Meet a member who never stops learning and growing. Each month AAPC selects a member who demonstrates exemplary leadership qualities. This month weve chosen Jennifer Lavoie RN CPC. Lavoie has enjoyed ... [ Read More ]